Go To

PD3041

強固級湧流保護器- RJ11 &雙絞線端子台
Wide Temperature
IEC 61643
UL 497B
透過 RJ11 連接器和端子塊提供配對保護
可安裝在控制櫃內
Downloads
訂購諮詢

益網科技的 PD3041 的強固級湧流保護器透過 RJ11 連接器和端子塊提供配對,可保護 DSL 設備免受危險的電湧、接地迴路以及因接線錯誤或閃電引起的放電所影響。 PD3041 具有完整的線對線和線對地湧流保護功能,非常適合在電力供應不穩定的區域以及電磁干擾過多的場所使用。應用安裝領域包括室外 IP 攝影機、Access Point 以及屋頂網路機櫃。

EtherWAN — "When Connectivity is Crucial."

強大的電壓突波保護

    • 透過 RJ11 連接器和端子塊提供配對保護

有彈性的安裝方式

    • 支援 DIN 導軌式安裝或桌面安裝

寬工作溫度範圍

    • 工作溫度範圍為 -40 至 75°C,吞吐量低於 100Mbps
 

Electrical

  • Maximum continuous operating voltage UC
    • ≤185VDC
  • Maximum continuous voltage UC (Wire-Wire)
    • ≤185VDC
  • Maximum continuous voltage UC (Wire-Ground)
    • ≤185VDC
  • Nominal current IN
    • ≤380mA (25°C)
  • Operating effective current IC at UC
    • ≤6μA
  • RResidual current IPE
    • ≤4μA
  • Nominal discharge surge current In (8/20) μs (Core-Core)
    • ≤5kA
  • Nominal discharge surge current In (8/20) μs (Core-Earth)
    • ≤5kA
  • Total surge current (8/20) μs
    • 10kA
  • Nominal pulse current Ian (10/1000) μs (Core-Core)
    • ≤100A
  • Nominal pulse current Ian (10/1000) μs (Core-Earth)
    • ≤100A
  • Nominal pulse current Ian (10/700) μs (Core-Core)
    • ≤150A
  • Nominal pulse current Ian (10/700) μs (Core-Earth)
    • ≤150A
  • Output voltage limitation at 1kV/μs (Core-Core) spike
    • ≤250V
  • Output voltage limitation at 1kV/μs (Core-Earth) spike
    • ≤250V
  • Residual voltage at In, (Conductor-Conductor)
    • ≤120V
  • Residual voltage at In, (Conductor-Ground)
    • ≤120V
  • Voltage protection level UP (Core-Core)
    • ≤300V (B2–100A)
    • ≤300V (C1–500A)
    • ≤300V (C2–5kA)
  • Voltage protection level UP (Core-Earth)
    • ≤300V (B2–100A)
    • ≤300V (C1–500A)
    • ≤300V (C2–5kA)
  • Response time tA (Core-Core)
    • ≤100ns
  • Response time tA (Core-Earth)
    • ≤100ns
  • Input attenuation aE, sym.
    • Typ. 0.5dB (≤5MHz)
    • Typ. 0.3dB (≤8MHz/150Ω)
    • Typ. 0.3dB (≤2.5MHz/600Ω)
  • Near-end crosstalk attenuation
    • ≤35dB (At 250MHz/100Ω)
  • Cut-off frequency fg (3dB), sym. in 100 Ohm system
    • Typ. 50MHz
  • Resistance in series
    • 3.3Ω ±10%
  • Surge carrying capacity in acc. with IEC 61643-21 (Core-Core)
    • B2 (4kV/100A)
    • C1 (1kV/500A)
    • C2 (10kV/5kA) (Terminal Block)
    • C2 (6kV/3kA) (RJ11)
  • Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth)
    • B2 (4kV/100A)
    • C1 (1kV/500A)
    • C2 (10kV/5kA) (Terminal Block)
    • C2 (6kV/3kA) (RJ11)
    • D1 (1kA)

Mechanical

  • Casing
    • Aluminum Case
    • IP20
  • Dimensions
    • 30 x 62.5 x 100mm (W x H x D)
    • (1.18" x 2.5" x 3.8")
  • Weight
    • 184g ±5%
  • Installation
    • RJ11 Connector / Terminal Block

Environment

  • Operating Temperature
    • -40 to 75°C (-40 to 167°F)
  • Storage Temperature
    • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity
    • 5% to 95% (non-condensation)

Regulatory Approvals

  • ISO
    • Manufactured in an ISO 9001 facility
  • Safety
    • UL 497B
  • EMI
    • CE
    • FCC Part 15 Class B
    • VCCI
  • Industrial Compliance
    • IEC 61643-21

Model

PD3041Hardened Surge Protection Device – RJ11 & Two Wire Terminal Block Type